CAE Healthcare®
Installing Müse® 2.1 SCE Development Software

Welcome to Müse 2.1 SCE Development Software. This document contains system requirements, installation instructions, tips and release notes for installing the Müse 2.1 SCE Development Software.

The Müse 2.1 SCE Development Software is intended for use with computers that do NOT have previous versions of Müse installed. If Müse is already installed on the computer, performing this Müse installation removes all user-created content and all installed learning modules. Please note that only the Müse installer for your specific simulator type and operating system should be used.

WARNING: This version of Müse does NOT support operation with a simulator and should NEVER be installed on any simulator workstation (Instructor Workstation, Remote Workstation or dedicated TouchPro client).

Table of Contents

Minimum System Requirements
Warnings
Prior to Installation
Macintosh® Installation Procedure
Windows® Installation Procedure
Tips for Running Müse in Windows
Deliberate Exclusions
Technological Limitations
Known Issues
Customer Service

Minimum System Requirements

Macintosh® Operating System
  • Mac OS 10.5.8
  • Safari® 5.x.x
  • Firefox® 17 ESR
  • Adobe Flash Player® 10.1.x.x
  • Adobe® Reader 9.x
Windows® Operating System
  • Windows 7 or 8, 32-bit or 64-bit
  • Firefox 17 ESR
  • Internet Explorer® 9
  • Adobe Flash Player 10.1.x.x
  • Adobe Reader 9.x
  • QuickTime 7.7.4 or later
Macintosh Hardware
  • Intel Core 2 Duo, 2.0 GHz
  • 2 GB DDR3 RAM
  • 8 GB Hard Drive Space Available
  • 1024x768 Screen Resolution
  • USB 2.0
  • Wireless 802.11b/g/n Ethernet Card
  • 100BASE-T Ethernet Adapter
  • Standard DVD+/-R Drive
Windows Hardware
  • Intel Core 2 Duo 2.4 GHz or Dual Core (i3 2.26 GHz or greater)
  • 4 GB DDR3 Memory
  • 32 GB Hard Drive Space Available
  • 1366x768 Screen Resolution
  • USB 2.0
  • Wireless 802.11b/g/n Ethernet Card
  • 100BASE-T Ethernet Adapter
  • Standard DVD+/-R Drive
Warnings
  • If Müse is already installed on the computer, performing this Müse installation removes all user-created content and all installed learning modules.
  • Only the Müse installer for your specific simulator type and operating system should be used.
  • If there is a local web server on the computer, this installation process replaces the index page with the Müse Start screen.
    • To check for an existing index page, open a web browser and go to http://localhost/.
  • Müse installs MySQL version 5.1.46 on Windows computers and requires the user to install MySQL version 5.1.46 on Macintosh computers.
    • In Windows, if MySQL is already installed, it must be uninstalled prior to installing Müse. Please note that uninstalling MySQL removes any existing databases. To check if MySQL is installed, from the Start menu, select Control Panel , click Uninstall a Program and review the list of installed software. If MySQL is listed, select it and click Uninstall.
    • In Mac OS, if MySQL is installed, it does not need to be uninstalled. However, if MySQL is installed, the MySQL root user must NOT have a password.
      • To check if MySQL is installed, from the Applications folder, navigate to the Utilities folder and double-click the Terminal application to open it. Once the Terminal application is open, enter ls -l /usr/local/mysql at the Terminal prompt. If the contents of the folder are listed, then MySQL is installed.
      • If MySQL is installed, check for a root password by entering /usr/local/mysql/bin/mysql -uroot at the Terminal prompt. If MySQL reports access denied, there is a password. If presented with a mysql> prompt, there is not a password. Enter quit at the mysql> prompt to exit MySQL.
      • If a root password is set for MySQL, enter /usr/local/mysql/bin/mysqladmin -uroot -p"current password" password "" at the Terminal prompt, where current password is the current password. If the current root password is unknown, please contact your system administrator.
  • In Windows, Müse installs PHP version 5.2.14.
    • If PHP is already installed, it must be uninstalled prior to installing Müse. To check if PHP is installed, from the Start menu, choose Control Panel, click Uninstall a Program and review the list of installed software. If PHP is listed, select it and click Uninstall.
  • In Windows, Müse must be uninstalled via the Windows Control Panel before Müse for another simulator type can be successfully installed.
  • In Windows, Müse must be uninstalled before it can be successfully reinstalled.
  • At various times during installation or operation of Müse, you may be prompted by security software (e.g., firewall and antivirus software) to allow operation to continue.
Prior to Installation
  • Visit http://get.adobe.com/flashplayer/ to download the latest version of Adobe Flash Player. When prompted, save the Adobe Flash Player installer file to an easily accessible location. Once the installer file has finished downloading, double-click the installer file and follow the on-screen prompts until Flash Player has finished installing.
  • Visit http://get.adobe.com/reader/ to download the latest version of Adobe Reader. When prompted, save the Adobe Reader installer file to an easily accessible location. Once the installer file has finished downloading, double-click the installer file and follow the on-screen prompts until Adobe Reader has finished installing.
  • If upgrading Müse on a Windows computer, visit http://www.apple.com/quicktime/download/ to download the latest version of QuickTime. When prompted, save the QuickTime installer file to an easily accessible loaction. Once the installer file has finished downloading, double-click the installer file and follow the on-screen prompts until QuickTime has finished installing.
  • If installing Müse on a Macintosh computer, download the installer for MySQL version 5.1.46 for Macintosh from http://downloads.mysql.com/archives/mysql-5.1/mysql-5.1.46-osx10.5-x86.dmg. Save the installer file to an easily accessible location (see the Macintosh Installation Procedure section for installation instructions).
  • Ensure that the system clock is set correctly.
  • Disable pop-up blocking in your web browser. The Müse installer and the Patient Records feature of Müse require that pop-up blocking be turned off. For assistance, consult your browser's help menu.
Macintosh Installation Procedure
  1. From the Apple menu, select System Preferences. The System Preferences window appears.
  2. From the System Preferences window, select Security & Privacy. The Security & Privacy window appears.
  3. In the Security & Privacy window, ensure the lock icon in the bottom left corner appears unlocked. If the lock does not appear unlocked, click the lock to make changes to the security and privacy settings. Your Mac login password may be required.
  4. Under Allow apps downloaded from, make a note of the current selection.
  5. Under Allow apps downloaded from, select Anywhere.
  6. Close the Security & Privacy window.
  7. Close the System Preferences window.
  8. If MySQL is already installed on the computer, ensure that there is no root password set (see the Warnings section for instructions).
  9. Navigate to the location where the downloaded MySQL version 5.1.46 installer file, mysql-5.1.46-osx10.5-x86.dmg, is saved (see the Prior to Installation section for download instructions).
  10. Double-click the mysql-5.1.46-osx10.5-x86.dmg file. A Finder window opens.
  11. Double-click mysql-5.1.46-osx10.5-x86.pkg in the Finder window. The MySQL installer launches.
  12. Follow the on-screen prompts until the MySQL software is finished installing. During the MySQL installation process, if informed that a newer version is already installed, please contact CAE Healthcare Customer Service.
  13. Double-click MySQL.prefPane in the Finder window. The System Preferences window appears.
  14. If a window appears stating that the preference pane is already installed, click Cancel. Otherwise, select Install for this user only when prompted.
  15. If a message appears saying the System Preferences must quit and reopen, click OK. The MySQL (32-bit) window appears.
  16. In the MySQL (32-bit) window, ensure MySQL is running. If MySQL is not running, click the Start MySQL Server button.
  17. Ensure the Automatically Start MySQL Server on Startup box is checked.
  18. Close the MySQL (32-bit) window.
  19. Close the System Preferences window.
  20. Double-click MySQLStartupItem.pkg in the Finder window. The MySQL Startup Item installer launches.
  21. Follow the on-screen prompts until the MySQL Startup Item is finished installing.
  22. From the Apple menu, select Restart to restart the computer.
  23. Navigate to the location where the downloaded Muse.pkg file is saved.
  24. Double-click Muse.pkg. The Müse installer launches.
  25. Follow the on-screen prompts. At one step of the installation, you may have to click Install for all users of this computer to enable the Continue button. Also note the Change Install Location button has no effect except to go back one step. After a few minutes, a message is displayed saying the software was successfully installed. Installation may take up to 10 minutes, despite the displayed estimated time remaining.
  26. If prompted to restart, follow the prompts to restart. If not prompted to restart, from the Apple menu, select Restart to restart the computer.
  27. From the Apple menu, select System Preferences. The System Preferences window appears.
  28. From the System Preferences window, select Security & Privacy. The Security & Privacy window appears.
  29. In the Security & Privacy window, ensure the lock icon in the bottom left corner of the screen appears unlocked. If the lock does not appear unlocked, click the lock to make changes to the security and privacy settings. Your Mac login password may be required.
  30. Under Allow apps downloaded from, restore the setting noted in step 4.
  31. Close the Security & Privacy window.
  32. Close the System Preferences window.
  33. Open a web browser (e.g., Safari) and enter http://localhost/ in the address field. The Müse Start screen appears.
  34. From the Müse Start screen, empty the cache:
    • In Safari version 5, click the Safari menu and select Empty Cache. In Safari version 6, go to the Preferences menu, select the Advanced tab and check the box next to Show Develop menu in menu bar. Then close the Preferences window and select the Develop menu. From the Develop menu, select Empty Caches.
    • For help emptying the cache in any other browser, please consult your browser's help menu.
  35. Click the Müse icon to launch Müse.
  36. To launch TouchPro, if desired, open a new browser tab or window, enter http://localhost/ in the address field and click the TouchPro icon.
IMPORTANT: The Müse software requires activation. The software can be used for 30 days without activation. At the end of the 30 days, the software must be activated for continued use. The software may be activated at any time after installation. For instructions on activating the software, see Activating and Deactivating Müse in the Documentation folder included with the downloaded Müse installer file.
Windows Installation Procedure
  1. Ensure MySQL and PHP are NOT installed on the computer (see the Warnings section for instructions).
  2. Navigate to the location where the Setup.exe file is saved.
  3. Double-click Setup.exe. The Müse installer launches.
  4. Follow the on-screen prompts.
  5. After a few minutes, a message appears saying the Müse setup wizard is complete.
  6. Click Finish to exit the setup wizard.
  7. Restart the computer.
  8. From the Start menu, select All Programs. Select METI and click Müse. The Müse Start screen appears in the default web browser.
  9. From the Müse Start screen, empty the cache:
    • In Internet Explorer, click the Tools menu and select Delete Browsing History. In the Delete Browsing History menu, ensure Preserve favorites website data is unchecked and ensure Temporary Internet files, Cookies and History are checked, then click Delete.
    • For help emptying the cache in any other browser, please consult your browser's help menu.
  10. Click the Müse icon to launch Müse.
  11. To launch TouchPro, if desired, open a new browser tab or window, enter http://localhost/ in the address field and click the TouchPro icon.
IMPORTANT: The Müse software requires activation. The software can be used for 30 days without activation. At the end of the 30 days, the software must be activated for continued use. The software may be activated at any time after installation. For instructions on activating the software, see Activating and Deactivating Müse in the Documentation folder included with the downloaded Müse installer file.
Tips for Running Müse in Windows
  • In Internet Explorer, if you are presented with a message bar that says, "Intranet settings are now turned off by default. Intranet settings are less secure than Internet settings. Click for options," click the message and select Don't show this message again.
  • Browser toolbars take up screen space, which may prevent the full Müse application from being displayed. It is recommended to hide all unnecessary toolbars.
  • Internet Explorer users are advised to use the browser in full-screen mode. Press the F11 key on your computer's keyboard to enable full-screen mode.
Deliberate Exclusions
  • Untranslated strings do not display English.
  • Ongoing medication infusion rates are not saved with patients.
  • Content sharing across simulator types is not supported.
  • No medications can be administered via scenarios.
  • Conditions, medications, and interventions cannot be set in the Patient Baseline.
  • ICP model is not supported.
  • Medication responses designed in support of HPS6 software need to be fully validated in the context of the new base patientsʼ physiology.
  • Simultaneously editing content on multiple instructor workstations is not supported (see “remote workstation” guidelines).
  • Custom TouchPro layouts, custom variables, custom conditions, and medication preferences are not exported with SCEs.
  • Running Müse in multiple tabs or windows on a single computer is not supported.
  • Text-size preference is not supported.

Technological Limitations
  • Due to differences in terminology, non-English text is sometimes wrapped or truncated.
  • Müse may fail to launch if the computer's system clock is set incorrectly during installation or afterwards.
  • When opening a second tab in the web browser, the layout of Müse and TouchPro are not automatically adjusted until the window is manually resized. 
  • The computer keyboard is not supported in the Flash-Player full-screen mode. Internet Explorer full-screen mode (F11 key) does support the computer keyboard. 
  • Real-time performance of the models is affected if Müse is run simultaneously with other applications.
Known Issues
  • Fluid bolus conditions are not applied correctly when used in scenarios.
  • For HPS, Bronchial Resistance Factor is not set upon connection to the simulator. It must be set after connecting to the simulator.
  • Pleth waveform shows undesired effects when switching to a pulseless rhythm.
  • Resetting a patient does not reload Baseline Parameters.
  • On HPS (Adult), ECS, PediaSIM ECS, and BabySIM, which only have a single control for bilateral needle decompression, intervention conditions for needle decompression are inappropriate. The conditions Right Decompression: Enable and Right Decompression: Disable have no effect. The conditions Left Decompression: Enable and Left Decompression: Disable can be used to toggle the Needle Decompression parameter, causing both decompression targets to be pressurized.
  • The Venous CO2 Shift parameter may not always lead to expected results and should be considered for use only for simulation of very specific pathologies. Patients saved after this parameter has been set in a simulation are not guaranteed to work well.
  • With the Third Degree AV Block cardiac rhythm, most cardiac cycles that include a ventricular beat do not produce palpable pulses.
  • On HPS (Adult), the NIBP monitor interface only supports systolic pressure of 67 to 200 mmHg, diastolic pressure of 42 to 175 mmHg and pulse pressure of 25 mmHg or greater.
  • After a successful activation or deactivation of Müse (offline or online) it may take up to one minute for Müse to reflect the new license state.
  • In Windows, PDFs occasionally fail to open. It is recommended to update Adobe Reader to version 10+.
  • History Log timestamps are incorrect after a system restore from backup.
  • As far as scenarios are concerned, the defibrillation event has a duration of two seconds. This may cause unintended transitions and can be worked around by incorporating a two-second delay into the scenario (using a time-in-state transition).
  • In the first moments of running an SCE, waveforms on widgets may be distorted.
  • With Müse, the delay between a cardiac pacing spike and the associated "captured" beat is 240 ms on METIman and 360 ms on other simulators, compared to 215 ms with HPS6 software. As a result, when some pacers are operated in demand/synchronous mode, the device detects the captured beat as a spontaneous beat, causing the next pacing spike to be delayed. Ultimately, though cardiac capture is achieved, the heart rate is significantly lower than expected.
Customer Service

CAE Healthcare Customer Service Headquarters
Monday - Friday from 7:00 a.m. to 6:00 p.m. ET
Toll Free: 1-866-462-7920
24-hour Hotline: 1-941-342-5605
[email protected]

CAE Healthcare Customer Service Canada
Monday - Friday from 8:00 a.m. to 5:00 p.m. ET
Toll Free: 1-877-223-6273
[email protected]

CAE Healthcare Customer Service EMEA
Monday - Friday from 8:00 a.m. to 5:00 p.m. CET
+49 (0) 6131 4950354
[email protected]

CAE Healthcare Customer Service UK and Ireland
Monday - Friday from 9:00 a.m. to 5:00 p.m. GMT
+44 (0) 800-917-1851
[email protected]

©2012 CAE Healthcare