CAE Healthcare®
|
|
Installing Müse® 2.2 SCE Development Software
|
|
Welcome to Müse 2.2 SCE Development Software. This document contains
system requirements, installation instructions, tips and release notes for
installing the Müse 2.2 SCE Development Software.
The Müse 2.2 SCE Development Software is intended for use with computers
that do NOT have previous versions of Müse installed. If Müse
is already installed on the computer, performing this Müse
installation removes all user-created content and all installed learning
modules. Please note that only the Müse installer for your specific
simulator type and operating system should be used.
|
WARNING:
This version of Müse does NOT support operation with a
simulator and should NEVER be installed on any simulator workstation
(Instructor Workstation, Remote Workstation or dedicated TouchPro client).
|
|
|
Table of Contents
|
|
|
|
Minimum System
Requirements
|
|
Macintosh® Operating System
- Mac
OS X 10.6x (minimum)
- Safari® 5.x.x or Firefox® 17 ESR (minimum)
- Adobe
Flash Player®
10.1.x.x (minimum)
- Adobe® Reader 9.x (or higher)
Windows® Operating System
- XP
Service Pack 2, Vista, Windows 7 or Windows 8
- Firefox
17 ESR, Internet Explorer®
9, or Safari 5.x.x (minimum)
- Adobe
Flash Player 10.1.x.x (minimum)
- Adobe
Reader 9.x (or higher)
Windows Hardware
- Intel
Core 2 Duo, 2.0 GHz (minimum)
- 4
GB DDR3 RAM (minimum)
- 32
GB Hard Drive Space Available
- 1366x768
Screen Resolution (minimum)
- USB
2.0
- Wireless
802.11b/g/n Ethernet Card
- 100BASE-T
Ethernet Adapter
- Standard
DVD+/-R Drive
Macintosh Hardware
- Intel
Core 2 Duo, 2.0 GHz (minimum)
- 2
GB DDR3 RAM (minimum)
- 8
GB Hard Drive Space Available
- 1024x768
Screen Resolution (minimum)
- USB
2.0
- Wireless
802.11b/g/n Ethernet Card
- 100BASE-T
Ethernet Adapter
- Standard
DVD+/-R Drive
|
|
Warnings
|
- If Müse
is already installed on the computer, performing this Müse
installation removes all user-created content and all installed learning
modules.
- Only
the Müse installer for your specific simulator type and operating
system should be used.
- If
there is a local web server on the computer, this installation process
replaces the index page with the Müse Start screen.
- To
check for an existing index page, open a web browser and go to
http://localhost/.
- Müse
installs MySQL version 5.1.46 on Windows computers and requires the user
to install MySQL version 5.1.46 on Macintosh computers.
- In
Windows, if MySQL is already installed, it must be uninstalled prior to
installing Müse. Please note that uninstalling MySQL removes any
existing databases. To check if MySQL is installed, from the Start
menu, select Control Panel , click Uninstall
a Program and review the list of installed software. If
MySQL is listed, select it and click Uninstall.
- In Mac OS, if MySQL is installed, it does not need to be
uninstalled. However, if MySQL is installed, the MySQL root user must
NOT have a password.
- To check if MySQL is installed, from
the Applications folder, navigate to the Utilities
folder and double-click the Terminal application to open it. Once the
Terminal application is open, enter ls -l /usr/local/mysql at
the Terminal prompt. If the contents of the folder are listed, then
MySQL is installed.
- If MySQL is installed, check for a root
password by entering /usr/local/mysql/bin/mysql -uroot at the
Terminal prompt. If MySQL reports access denied, there is a
password. If presented with a mysql> prompt, there is not a
password. Enter quit at the mysql> prompt to exit
MySQL.
- If a root password is set for MySQL,
enter /usr/local/mysql/bin/mysqladmin -uroot -p"current
password" password "" at the Terminal prompt, where
current password is the current password. If the current root
password is unknown, please contact your system administrator.
- In
Windows, Müse installs PHP version 5.2.14.
- If
PHP is already installed, it must be uninstalled prior to installing
Müse. To check if PHP is installed, from the Start menu,
choose Control Panel, click Uninstall
a Program and review the list of installed software. If PHP
is listed, select it and click Uninstall.
- In
Windows, Müse must be uninstalled via the Windows Control Panel
before Müse for another simulator type can be successfully
installed.
- In
Windows, Müse must be uninstalled before it can be successfully
reinstalled.
- At
various times during installation or operation of Müse, you may be
prompted by security software (e.g., firewall and antivirus software) to
allow operation to continue.
|
|
Prior to
Installation
|
- Visit http://get.adobe.com/flashplayer/
to download the latest version of Adobe Flash Player. When prompted,
save the Adobe Flash Player installer file to an easily accessible
location. Once the installer file has finished downloading, double-click
the installer file and follow the on-screen prompts until Flash Player
has finished installing.
- Visit http://get.adobe.com/reader/
to download the latest version of Adobe Reader. When prompted, save the
Adobe Reader installer file to an easily accessible location. Once the
installer file has finished downloading, double-click the installer file
and follow the on-screen prompts until Adobe Reader has finished
installing.
- If
upgrading Müse on a Windows computer, visit http://www.apple.com/quicktime/download/
to download the latest version of QuickTime. When prompted, save the
QuickTime installer file to an easily accessible loaction. Once the
installer file has finished downloading, double-click the installer file
and follow the on-screen prompts until QuickTime has finished
installing.
- If
installing Müse on a Macintosh computer, download the installer for
MySQL version 5.1.46 for Macintosh from http://downloads.mysql.com/archives/mysql-5.1/mysql-5.1.46-osx10.5-x86.dmg.
Save the installer file to an easily accessible location (see the Macintosh
Installation Procedure section for installation instructions).
- Ensure
that the system clock is set correctly.
- Disable
pop-up blocking in your web browser. The Müse installer and
the Patient Records feature of Müse require that pop-up
blocking be turned off. For assistance, consult your browser's help
menu.
|
|
Macintosh
Installation Procedure
|
- From
the Apple menu, select System Preferences. The System
Preferences window appears.
- From
the System Preferences window, select Security & Privacy. The
Security & Privacy window appears.
- In
the Security & Privacy window, ensure the lock icon in the bottom
left corner appears unlocked. If the lock does not appear unlocked,
click the lock to make changes to the security and privacy settings.
Your Mac login password may be required.
- Under
Allow apps downloaded from, make a note of the current
selection.
- Under
Allow apps downloaded from, select Anywhere.
- Close
the Security & Privacy window.
- Close
the System Preferences window.
- If
MySQL is already installed on the computer, ensure that there is no root
password set (see the Warnings section for instructions).
- Navigate
to the location where the downloaded MySQL version 5.1.46 installer file,
mysql-5.1.46-osx10.5-x86.dmg, is saved (see the Prior to
Installation section for download instructions).
- Double-click
the mysql-5.1.46-osx10.5-x86.dmg file. A Finder window opens.
- Double-click
mysql-5.1.46-osx10.5-x86.pkg in the Finder window. The MySQL
installer launches.
- Follow
the on-screen prompts until the MySQL software is finished installing.
During the MySQL installation process, if informed that a newer version
is already installed, please contact CAE Healthcare Customer
Service.
- Double-click
MySQL.prefPane in the Finder window. The System Preferences
window appears.
- If
a window appears stating that the preference pane is already installed,
click Cancel. Otherwise, select Install for this user only
when prompted.
- If
a message appears saying the System Preferences must quit and reopen,
click OK. The MySQL (32-bit) window appears.
- In
the MySQL (32-bit) window, ensure MySQL is running. If MySQL
is not running, click the Start MySQL Server button.
- Ensure
the Automatically Start MySQL Server on Startup box is checked.
- Close
the MySQL (32-bit) window.
- Close
the System Preferences window.
- Double-click
MySQLStartupItem.pkg in the Finder window. The MySQL Startup Item
installer launches.
- Follow
the on-screen prompts until the MySQL Startup Item is finished
installing.
- From
the Apple menu, select Restart to restart the computer.
- Navigate
to the location where the downloaded Muse.pkg file is saved.
- Double-click
Muse.pkg. The Müse installer launches.
- Follow
the on-screen prompts. At one step of the installation, you may have to
click Install for all users of this computer to enable the Continue
button. Also note the Change Install Location button has no effect
except to go back one step. After a few minutes, a message is displayed
saying the software was successfully installed. Installation may take up
to 10 minutes, despite the displayed estimated time remaining.
- If prompted
to restart, follow the prompts to restart. If not prompted to restart,
from the Apple menu, select Restart to restart the
computer.
- From
the Apple menu, select System Preferences. The System
Preferences window appears.
- From
the System Preferences window, select Security & Privacy. The
Security & Privacy window appears.
- In
the Security & Privacy window, ensure the lock icon in the bottom
left corner of the screen appears unlocked. If the lock does not appear
unlocked, click the lock to make changes to the security and privacy
settings. Your Mac login password may be required.
- Under
Allow apps downloaded from, restore the setting noted in step 4.
- Close
the Security & Privacy window.
- Close
the System Preferences window.
- Open
a web browser (e.g., Safari) and enter http://localhost/ in the address
field. The Müse Start screen appears.
- From
the Müse Start screen, empty the cache:
- In
Safari version 5, click the Safari menu and select Empty
Cache. In Safari version 6, go to the Preferences menu,
select the Advanced tab and check the box next to Show
Develop menu in menu bar. Then close the Preferences window and
select the Develop menu. From the Develop menu,
select Empty Caches.
- For
help emptying the cache in any other browser, please consult your
browser's help menu.
- Click
the Müse icon to launch Müse.
- To
launch TouchPro, if desired, open a new browser tab or window, enter http://localhost/
in the address field and click the TouchPro icon.
IMPORTANT:
The Müse software requires activation. The software can be used for 30
days without activation. At the end of the 30 days, the software must be
activated for continued use. The software may be activated at any time after
installation. For instructions on activating the software, see Activating and
Deactivating Müse in the Documentation folder included with the
downloaded Müse installer file.
|
|
Windows Installation
Procedure
|
- Ensure
MySQL and PHP are NOT installed on the computer (see the Warnings
section for instructions).
- Navigate
to the location where the Setup.exe file is saved.
- Double-click
Setup.exe. The Müse installer launches.
- Follow
the on-screen prompts.
- After
a few minutes, a message appears saying the Müse setup wizard is
complete.
- Click
Finish to exit the setup wizard.
- Restart
the computer.
- From
the Start menu, select All Programs. Select METI
and click Müse. The Müse Start screen appears in the
default web browser.
- From
the Müse Start screen, empty the cache:
- In
Internet Explorer, click the Tools menu and select Delete
Browsing History. In the Delete Browsing History menu, ensure Preserve
favorites website data is unchecked and ensure Temporary
Internet files, Cookies and History are
checked, then click Delete.
- For
help emptying the cache in any other browser, please consult your
browser's help menu.
- Click
the Müse icon to launch Müse.
- To
launch TouchPro, if desired, open a new browser tab or window, enter http://localhost/
in the address field and click the TouchPro icon.
IMPORTANT:
The Müse software requires activation. The software can be used for 30 days
without activation. At the end of the 30 days, the software must be activated
for continued use. The software may be activated at any time after
installation. For instructions on activating the software, see Activating and
Deactivating Müse in the Documentation folder included with the
downloaded Müse installer file.
|
|
Tips for Running
Müse in Windows
|
- In
Internet Explorer, if you are presented with a message bar that says,
"Intranet settings are now turned off by default. Intranet settings
are less secure than Internet settings. Click for options," click
the message and select Don't show this message again.
- Browser
toolbars take up screen space, which may prevent the full Müse
application from being displayed. It is recommended to hide all unnecessary
toolbars.
- Internet
Explorer users are advised to use the browser in full-screen mode. Press
the F11 key on your computer's keyboard to enable full-screen mode.
|
|
Deliberate
Exclusions
|
- Untranslated
strings do not display English.
- Ongoing
medication infusion rates are not saved with patients.
- Content
sharing across simulator types is not supported.
- No
medications can be administered via scenarios.
- Conditions,
medications, and interventions cannot be set in the Patient Baseline.
- ICP
model is not supported.
- Medication
responses designed in support of HPS6 software need to be fully
validated in the context of the new base patientsʼ
physiology.
- Simultaneously
editing content on multiple instructor workstations is not supported
(see “remote workstation” guidelines).
- Custom
TouchPro layouts, custom variables, custom conditions, and medication
preferences are not exported with SCEs.
- Running
Müse in multiple tabs or windows on a single computer is not
supported.
- Text-size
preference is not supported.
|
|
Technological
Limitations
|
- Due
to differences in terminology, non-English text is sometimes wrapped or
truncated.
- Müse
may fail to launch if the computer's system clock is set incorrectly
during installation or afterwards.
- When
opening a second tab in the web browser, the layout of Müse and
TouchPro are not automatically adjusted until the window is manually
resized.
- The
computer keyboard is not supported in the Flash-Player full-screen mode.
Internet Explorer full-screen mode (F11 key) does support the computer
keyboard.
- Real-time
performance of the models is affected if Müse is run simultaneously
with other applications.
|
|
Known Issues
|
- Fluid
bolus conditions are not applied correctly when used in scenarios.
- For
HPS, Bronchial Resistance Factor is not set upon connection to the
simulator. It must be set after connecting to the simulator.
- Pleth
waveform shows undesired effects when switching to a pulseless rhythm.
- Resetting
a patient does not reload Baseline Parameters.
- On
HPS (Adult), ECS, PediaSIM ECS, and BabySIM, which only have a single
control for bilateral needle decompression, intervention conditions for
needle decompression are inappropriate. The conditions Right
Decompression: Enable and Right Decompression: Disable have no
effect. The conditions Left Decompression: Enable and Left
Decompression: Disable can be used to toggle the Needle
Decompression parameter, causing both decompression targets to be
pressurized.
- The Venous
CO2 Shift parameter may not always lead to expected results and should
be considered for use only for simulation of very specific pathologies.
Patients saved after this parameter has been set in a simulation are not
guaranteed to work well.
- With
the Third Degree AV Block cardiac rhythm, most cardiac cycles that
include a ventricular beat do not produce palpable pulses.
- On
HPS (Adult), the NIBP monitor interface only supports systolic pressure
of 67 to 200 mmHg, diastolic pressure of 42 to 175 mmHg and pulse
pressure of 25 mmHg or greater.
- After
a successful activation or deactivation of Müse (offline or online)
it may take up to one minute for Müse to reflect the new license
state.
- In
Windows, PDFs occasionally fail to open. It is recommended to update
Adobe Reader to version 10+.
- History
Log timestamps are incorrect after a system restore from backup.
- As
far as scenarios are concerned, the defibrillation event has a duration
of two seconds. This may cause unintended transitions and can be worked
around by incorporating a two-second delay into the scenario (using a
time-in-state transition).
- In
the first moments of running an SCE, waveforms on widgets may be
distorted.
- With
Müse, the delay between a cardiac pacing spike and the associated
"captured" beat is 240 ms on METIman and 360 ms on other simulators,
compared to 215 ms with HPS6 software. As a result, when some pacers are
operated in demand/synchronous mode, the device detects the
captured beat as a spontaneous beat, causing the next pacing spike to be
delayed. Ultimately, though cardiac capture is achieved, the heart rate
is significantly lower than expected.
|
|
Customer Service
|
|
CAE Healthcare Customer Service
Headquarters
Monday - Friday from 7:00 a.m. to 6:00 p.m. ET
Toll Free: 1-866-462-7920
24-hour Hotline: 1-941-342-5605
[email protected]
CAE Healthcare Customer Service Canada
Monday - Friday from 8:00 a.m. to 5:00 p.m. ET
Toll Free: 1-877-223-6273
[email protected]
CAE Healthcare Customer Service EMEA
Monday - Friday from 8:00 a.m. to 5:00 p.m. CET
+49 (0) 6131 4950354
[email protected]
CAE Healthcare Customer Service UK and Ireland
Monday - Friday from 9:00 a.m. to 5:00 p.m. GMT
+44 (0) 800-917-1851
[email protected]
|
|
©2012 CAE Healthcare
|